pH Electrodes

High quality glass and polymer encased pH electrodes with small diameter stems that
are particularly useful for electrochemical reaction cell applications.-
 

Ag/AgCl Combination Electrodes

  These Ag/AgCL Combination Electrodes feature narrow insertion stems that allow measurements of small samples inside of test tubes and narrow neck vessels. Available in several different stem lengths. All of these electrodes feature Ag/AgCl half-cells. The oeprational characteristics of the Ag/AgCl half-cell are given below.

Silver/Silver Chloride Half-Cell (Ag/AgCl)
Temperature Range:
-5° - 100° C Continuous Use
-5° - 130° C Intermittent Use
Ag/AgCl is a very stable half-cell that has a much higher working temperature than the calomel. Recommended for all applications except those involving TRIS buffer, proteins, metal ions, sulfides, or other substances that will react with either Ag or AgCl.

Electrode Descriptions


Fig. A. Ag/AgCl Combination Electrode. Standard length with 8mm O.D. insertion stem. 0-12 pH.
p/n 66-C1381A121  

Fig. B. Ag/AgCl Combination Electrode. Standard length with 8mm O.D. insertion stem. Electrode is complete with removable plastic bulb guard that protects the glass bulb from impact during use. 0-12 pH
p/n 66-C1382A121 

Fig. C. Long, Ag/AgCl Combination Electrode with 6mm O.D. insertion stem. 0-12 pH.
p/n 66-C1361A121 

Fig. D. Long, Ag/AgCl Combination Electrode with 8mm O.D. insertion stem. 0-12 pH.
p/n 66-C1383A121

Fig. E. Extra long, Ag/AgCl Combination Electrode with 8mm O.D. insertion stem. 0-12 pH.
p/n 66-C1384A121 


Polymer Bodied pH Combination Electrodes


  These combination electrodes are designed for applications where rough handling and breakage are major problems, the bodies of these electrodes are made from impact resistant expoxy tubing

Particularly Suited for use with portable pH meters in the field and to make a spot check measurements of production processes.

Available with either Ag/AgCl or Calomel reference half-cells. The Ag/AgCl half-cell has the higher temperature rating, whiel teh Calomel hald-cell is recommended when measuring meats, broths, or any protein bearing sample.

Also available with either
-liquid-filled/refillable
-get-filled/sealed refernece.
The gel-filled design offers excellent results with minimum maintenance. The liquid refillable design offers measurement accuracy and reproducibility approaching that of a glass laboratory electrode.

All polymer electrodes utilize GP bulb glass featuring fast response over the range if 0-12pH.

All probes completely shielded for a stable signal while being hand held

All probes can be used continuously 0-80°C. The Ag/AgCl probes can be used intermittently up to 100°C.

 
Electrode Descriptions

Fig. A. Rugged field pH electrode
Rugged extra thick polymer wall(0.050") makes this the first choice for handled field work. Dual ceramic pin wicks. 0-12 pH


p/n 66-C2451C-12A  Ag/AgCl/gel-filled/sealed, 12mm OD

Fig. B. General purpose design for both lab and field. Bulb is guarded from accidental impact. Coaxial ceramic reference wick. 0-12 pH

p/n 66-C2507A-121  Ag/AgCl/liquid-filled/refillable, 12mm OD
p/n 66-C2507A-12A  Ag/AgCl/gel filled/sealed, 12mm OD
p/n 66-C2507A-125  Calomel/liquid-filled/refillable, 12mm OD
p/n 66-C2507A-12Y  Calomel/gel-filled/sealed, 12mm OD

Fig. C. General purpose design with a removable bulb guard. Coaxial ceramic wick. 0-12 pH.
p/n 66-C2506A-12A   Ag/AgCl/gel filled/sealed, 12mm OD
p/n 66-C2506A-121   Ag/AgCl/liquid-filled/refillable, 12mm OD

Fig. D. Long narrow stem design is ideal for measuring small samples in test tubes or narrow neck vessels. Ceramic pin wick. 0-12 pH
p/n 66-C2369A-12A Long Narrow Stem, 6m OD x 183mm


Micro-pH Combination Electrodes

 These Calomel Micro pH Combination Glass Electrodes with 4mm-3.5mm O.D. insertion stems feature ultra-thin insertion stems and miniature pH bulbs for measurement of the smallest of samples. Extra long stem lengths are available for access to long stem vessels, such as flow cells or NMR tubes.

Electrode Descriptions


Fig. A. Calomel Combination Electrode with 4mm O.D. stem, intermediate length.  Sturdy and versatile probe for measuring small samples in cuvets and small lab glassware. 0-12 pH with 132 mm stem


p/n 66-0088 with BNC connector
p/n 66-0089
with SC connector
p/n 66-0090
with MA connector
p/n 66-0091
with MB connector
p/n 66-0092
with RA connector
p/n 66-0093
with BB connector
p/n 66-0094
with BP connector
p/n 66-0095
with DN connector
p/n 66-0096
with DB connector

Fig. B. Calomel Combination Electrode. Standard length with 3mm O.D. pH bulb and 3.5mm insertion stem. 0-12 pH
with 55 mm stem

p/n 66-0067 with BNC connector
p/n 66-0097 with SC connector
p/n 66-0098 with MA connector
p/n 66-0099 with MB connector
p/n 66-0100 with RA connector
p/n 66-0101 with BB connector
p/n 66-0102 with BP connector
p/n 66-0103 with DN connector
p/n 66-0104 with DB connector

Fig. C.Extra long 3.5mm O.D. stem allows this calomel combination electrode to measure samples at the bottom of 7" long NMR tubes. 0-12 pH
with 183 mm stem.

p/n 66-0069 with BNC connector
p/n 66-0105 with SC connector
p/n 66-0106 with MA connector
p/n 66-0107 with MB connector
p/n 66-0108 with RA connector
p/n 66-0109 with BB connector
p/n 66-0110 with BP connector
p/n 66-0111 with DN connector
p/n 66-0112 with DB connector


Please read the following information, 'How to Order an Electrode', prior to placement of your order.

Warranty: There is a one year manufacturer's warranty if an electrode is defective.

Please call or fax us about pricing and connector information or questions about ordering.


  How to Order an Electrode

Please read the following information prior to order placement. There are four parts of information required for each item:

1. Electrode Model Number - Each electrode has a ten character model number.

2. Cable Type - All lab electrodes are equipped with Type A, low noise, 3mm, coaxial cable.

3. Cable Length - The cable length is expressed in feet immediately after the cable type.

Example: "-A03" stands for a three foot cable which is standard
                  for all our electrodes.  Follow model numbers by
                  a "-DK" for a threaded electrode cap.

4. Connector -The cable length is followed by a two letter designation for the proper connector.


 


   Connectors for Combination Electrodes


 